This Professional Auto-range Digital Multimeter (VC97) is made by VICTOR brand. It is a high performance and accuracy with large LCD display to measure DC and AC voltage, DC and AC current, Resistance, Capacitance, Frequency, Temperature, Duty circle, Transistor, Diode and Continuity Test.
The designed parameter include: unit indication, data hold (HOLD), relatively measuring (REL), AUTO/MANUAL range, auto off and buzzer sounds. This multimeter is most suitable for use on production lines or lab, R & D, maintenance and repairing work.
Features
- Dual-slop DC/AC converter CMOS technology for auto-zero, polarity selection and over-range indication.
- Full overload protection
- New type holster, streamline design
- 3 ¾ digit Large LCD Display
- Metallic screen board with stronger antimagnetic and anti-interferential function.
- Full function protection, anti-high voltage circuit design.
- Low battery display indication
General Specifications
- Display: 3 ¾ digit Large LCD with a max readings of 3999.
- Measuring method: Dual-slope integrating A/D Converter System featuring CMOS technology for auto-zero, polarity selection, and over-range indication.
- Sampling Rate: approx. 3 Times / Second
- Max Common Mode Voltage: 500V DC/AC RMS
- Range Selection Method: Automatic and Manual
- Polarity: Automatic Negative Polarity Indication
- Over range indication: Only the MSD "OL" display
- Safety Standards: CE; EMC/LVD; IEC1010
- Pollution Degree 2, Over voltage category II or double insulation II
- Operating Temperature: 0 ~ 40 °C (32 ~ 104 °F)
- Operating Humidity: below 80% RH
- Storage Temperature: -10 ~ 50 °C (14 ~ 122 °F)
- Storage Humidity: below 80% RH
- Low battery display auto turn off (after turn on 15 minutes)
- Power: 2 x 1.5 V AAA batteries (not included)
- Dimensions: 190 (H) x 93.5 (W) x 37 (D) mm (7.48' x 3.68' x 1.46' inch)
- Weight: approx. 420g (14.82 oz)
Electrical Specifications:
Accuracy is ±(percentage of reading + number of digit) at (23±5) °C, <75% RH.
DC Voltage
|
Range |
Accuracy |
Resolution |
|
400 mV |
± (0.5% + 4d) |
0.1 mV |
|
4 V |
1 mV |
|
|
40 V |
10 mV |
|
|
400 V |
100 mV |
|
|
1000 V |
± (1.0% + 6d) |
1 V |
Input impedance: 400 mV range: more than 40 MΩ ; other range: 10 MΩ
Overload protection: 1000 V DC or AC peak value
DC mV
|
Range |
Accuracy |
Resolution |
|
400 mV |
± (0.5% + 4d) |
0.1 mV |
AC Voltage
|
Range |
Accuracy |
Resolution |
|
4V |
± (0.8% + 10d) |
1 mV |
|
40 V |
10 mV |
|
|
400 V |
100 mV |
|
|
750 V |
± (1.0% + 10d) |
1 V |
Input impedance: 400 mV range: more than 40 MΩ ; other range: 10 MΩ
Frequency response: 750 v range: 40-100 Hz ; other range: 40-400 Hz
Overload protection: 1000 V DC / 750 V AC RMS
Indication : mean value response (rms of sine wave)
Resistance
|
Range |
Accuracy |
Resolution |
|
400 Ω |
± (0.8% + 5d) |
0.1 Ω |
|
4k Ω |
± (0.8% + 4d) |
1 Ω |
|
40k Ω |
10 Ω |
|
|
400k Ω |
100 Ω |
|
|
4M Ω |
1 kΩ |
|
|
40M Ω |
± (1.2% + 10d) |
10 kΩ |
Overload protection: 250V DC/AC Peak Value
Open circuit voltage: 400 mV
Note: at 400 Ω range, should short the test leads and measure the resistance of the wire, then minus from measuring.
DC Current
|
Range |
Accuracy |
Resolution |
|
400 μA |
± (1.0% + 10d) |
0.1 μA |
|
4000 μA |
1 μA |
|
|
40 mA |
± (1.2% + 8d) |
10 μA |
|
400 mA |
100 μA |
|
|
10 A |
± (1.2% + 10d) |
100 mA |
Overload protection: 0.5A / 250V fuse ; 10A / 250V fuse
Max measuring voltage: Full scale mA range: 1.2 V ; A range: 100 mV
Max input current: 10A (up to 15 seconds)
AC mV
|
Range |
Accuracy |
Resolution |
|
400 mV |
± (1.6% + 8d) |
0.1 mV |
AC Current
|
Range |
Accuracy |
Resolution |
|
400 uA |
± (1.5% + 10d) |
0.1 uA |
|
4000 uA |
1 uA |
|
|
40 mA |
10 uA |
|
|
400 mA |
100 uA |
|
|
10 A |
± (2.0% + 15d) |
100 mA |
Overload protection: 0.5A / 250V fuse ; 10A / 250V fuse
Max measuring voltage: Full scale mA range: 1.2 V ; A range: 100 mV
Max input current: 10A (up to 15 seconds)
Frequency response: 10A range: 40-100 Hz ; other range: 40-400 Hz
Capacitance
|
Range |
Accuracy |
Resolution |
|
4 nF |
± (2.5% + 20d) |
1 pF |
|
40 nF |
± (3.5% + 8d) |
10 pF |
|
400 nF |
100 pF |
|
|
4 uF |
1 nF |
|
|
40 uF |
10 nF |
|
|
200 uF |
± (5.0% + 10d) |
100 nF |
Overload protection: 250V DC/AC Peak Value
Frequency
|
Range |
Accuracy |
Resolution |
|
100 Hz |
± (0.5% + 10d) |
0.01 Hz |
|
1000 Hz |
± (0.5% + 10d) |
0.1 Hz |
|
10 kHz |
|